forked from 1b-agent/opencadstudio-upstream
- A blank script line outside a command repeats the last command through dispatch_command, as the command line's empty Enter does. - ZOOMFACTOR bound docs describe the SETVAR range the PR widened, and the test keeps checking the value the Options field reaches. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
59b76ada5c
commit
fd12ef7768
3 files changed
+10
-8
No files matched your search
@@ -1180,8 +1180,9 @@ impl OpenCADStudio {
|
|||||||
if self.tabs[i].active_cmd.is_some() {
|
if self.tabs[i].active_cmd.is_some() {
|
||||||
return self.feed_command(StepInput::Enter);
|
return self.feed_command(StepInput::Enter);
|
||||||
}
|
}
|
||||||
|
// Same repeat the command line's empty Enter gives.
|
||||||
if let Some(cmd) = self.tabs[i].last_cmd.clone() {
|
if let Some(cmd) = self.tabs[i].last_cmd.clone() {
|
||||||
return self.run_command_line(&cmd);
|
return self.dispatch_command(&cmd);
|
||||||
}
|
}
|
||||||
return Task::none();
|
return Task::none();
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -3617,6 +3617,9 @@ mod tests {
|
|||||||
let _ = app.run_command_line("SETVAR ZOOMFACTOR 2");
|
let _ = app.run_command_line("SETVAR ZOOMFACTOR 2");
|
||||||
assert_eq!(app.zoom_factor, 500, "and neither is 2");
|
assert_eq!(app.zoom_factor, 500, "and neither is 2");
|
||||||
|
|
||||||
|
// What the Options field reached is still reported here.
|
||||||
|
let _ = app.update(crate::app::Message::ZoomFactorInputChanged("250".into()));
|
||||||
|
assert_eq!(app.zoom_factor, 250);
|
||||||
let _ = app.run_command_line("SETVAR ZOOMFACTOR 60");
|
let _ = app.run_command_line("SETVAR ZOOMFACTOR 60");
|
||||||
assert_eq!(app.zoom_factor, 60);
|
assert_eq!(app.zoom_factor, 60);
|
||||||
}
|
}
|
||||||
|
|||||||
+5
-7
@@ -171,13 +171,11 @@ pub fn clamp_right_click_hold_ms(v: i32) -> i32 {
|
|||||||
|
|
||||||
/// ZOOMFACTOR bounds.
|
/// ZOOMFACTOR bounds.
|
||||||
///
|
///
|
||||||
/// `ZOOM_FACTOR_SYSVAR_MAX` is the range the system variable has: `SETVAR
|
/// `ZOOM_FACTOR_SYSVAR_MAX` is where the Options slider stops: the range the
|
||||||
/// ZOOMFACTOR` accepts 3 to 100 and nothing else, so a drawing session set
|
/// variable has elsewhere. Both the Options field and `SETVAR ZOOMFACTOR`
|
||||||
/// up on the command line stays within the range the variable has everywhere
|
/// reach `ZOOM_FACTOR_MAX` for anyone who wants a faster wheel; the value
|
||||||
/// else. The Options window is the app's own surface and reaches
|
/// lives only in this application's own configuration file, so it is nobody
|
||||||
/// `ZOOM_FACTOR_MAX` for anyone who wants a faster wheel than the variable
|
/// else's to read.
|
||||||
/// can express; that value lives only in this application's own
|
|
||||||
/// configuration file, so it is nobody else's to read.
|
|
||||||
pub const ZOOM_FACTOR_MIN: i32 = 3;
|
pub const ZOOM_FACTOR_MIN: i32 = 3;
|
||||||
pub const ZOOM_FACTOR_SYSVAR_MAX: i32 = 100;
|
pub const ZOOM_FACTOR_SYSVAR_MAX: i32 = 100;
|
||||||
pub const ZOOM_FACTOR_MAX: i32 = 500;
|
pub const ZOOM_FACTOR_MAX: i32 = 500;
|
||||||
|
|||||||
Reference in new issue
Block a user