forked from 1b-agent/opencadstudio-upstream
Named parameters (docs/named_parameters_design.md, stages 3-4): - ParameterTable (src/scene/named_parameters.rs): a document-wide table of named formulas, each resolved through a shared expression evaluator with cross-parameter references, cycle detection, and division-by-zero/parse error reporting. SketchConstraint::driving_param becomes DrivingValue (Literal | Named) instead of a bare f64, resolved at solve time by sketch_solve::build_constraint via Scene::named_parameters. - Persistence (src/scene/named_parameters_persist.rs): same lazy XRecord model sketch_persist.rs already established, synced around open/save. Bumps the sketch-constraint XRecord's own format version (1 -> 2) since DrivingValue's shape doesn't line up with a version-1 blob's bytes. - PARAMETERS command and its editor (src/ui/window/named_parameters.rs): add/remove/edit rows, live validation, duplicate-name detection: Apply defines the table and re-solves every constraint scope with a named-parameter-driven constraint (command_driver.rs). Distance/Angle constraint prompts (modules/draw/constrain/value.rs) now accept either a literal or an existing parameter's name, mirroring how the constraint's own value prompt already worked. - Undo scope-down carried over from this project's own established pattern (constraint-system stage 9): the geometry an Apply moves is one undo step, but the parameter table edit itself has no undo entry yet — a documented follow-up, not a silent gap. UI scale setting (src/app/settings.rs, app/mod.rs, ui/window/options.rs): a whole-interface scale percentage (50-200%), wired directly into iced's own per-window scale_factor hook rather than per-panel font-size plumbing, so it applies immediately to every panel, dialog, and the ribbon at once. Persisted alongside the existing lineweight-display-scale setting. OPTIONS/OP command dispatch (app/commands/view.rs, app/commands/mod.rs): OPTIONS was registered for autocomplete but had no dispatch arm — the Start-tab welcome screen's own button was the only way to reach it. Found live-testing the UI-scale setting, unrelated to that feature itself. "OP" is AutoCAD's own short alias. help/: a new self-contained static user-help manual (manual.md as the authored source, tools/build_help.py splits it into the committed static HTML pages plus search index) — not yet wired into the application. 64 new/updated tests across the named-parameters and constraint-prompt changes. Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Help images
Place optimized screenshots and workflow illustrations in this directory.
Use descriptive lowercase filenames, include meaningful alternative text in
manual.md, crop away unrelated desktop content, and avoid confidential drawing
names or paths. Prefer WebP or optimized PNG and keep each image at the smallest
resolution that remains legible on a high-density display.