forked from 1b-agent/fieldcraft-upstream
verification: Euler columns and Bryan's plate in buckling steps
buckle-euler-pinned and buckle-euler-cantilever (hex20 columns, −0.18 % from Euler with Engesser's shear correction) and buckle-plate-square (a simply supported square plate, b/t = 100, −0.39 % from k = 4; the support and thickness choices in its README). ROADMAP and parity updated, docs/oracle.md regenerated. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01UhhZMBTviDQxZvwnyP89fo
This commit is contained in:
1 parent
1b57e2e672
commit
788edbbddd
15 files changed
+161
-3
No files matched your search
@@ -0,0 +1,5 @@
|
||||
# Euler buckling of a clamped–free column of solids
|
||||
|
||||
A square column, length 10, side 1, E = 1000, ν = 0 (2 × 2 × 10 hex20), clamped at its base and
|
||||
pressed by a unit dead pressure on its free top: effective length 20. Reference: Euler with
|
||||
Engesser's shear correction.
|
||||
Reference in new issue
Block a user