jyvikoandClaude Opus 5.5 8871f6721d solver: mortar contact in nonlinear static steps
Frictionless contact pairs enforced by an augmented Lagrangian: nodal pressures from the
mortar weighted gaps, Uzawa updates after each converged increment until the gaps are within
1e-5 of the element thickness, and the consistent tangent (outer products of the weighted
gap gradients and the pressure-weighted Hessians from the automatic differentiation of the
mortar integrals). Finite sliding searches and integrates on the current configuration every
evaluation; without nonlinear geometry the pairs and their mortar integrals are fixed in the
reference configuration (small sliding, linear and exact). The tangent's pattern takes the
face pairs' blocks; the step cuts back when the active set chatters. Initial overclosure is
offset or refused; general contact, 2D models and arc length are refused by name; the linear
analyses refuse contact by name instead of the mesh.

With contact the convergence force scale comes from the converged states, the loads and the
current state. The loads-and-reactions balance check takes the nodal reactions into its scale
(no spurious warning for a part squeezed between held faces).

Tests: the contact patch test on non-matching hex8/tet4 meshes (exact with small sliding,
to 1e-4 with finite sliding), Hertz cylinder on a flat (peak pressure within 3%, half-width
bracketed) with quadratic Newton convergence, overclosure, thread-count determinism and the
refusals; Hertz sphere on a flat (heavy).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UhhZMBTviDQxZvwnyP89fo
2026-10-14 14:58:32 -04:00
jyvikoandClaude Opus 5.5 1b57e2e672 solver, model, engine: linear buckling steps
Procedure::Buckle {modes, shift}: the step's loads as a linear preload, K_σ from its stresses,
and (K + λ K_σ) φ = 0 by block Lanczos in the K inner product: K⁻¹(−K_σ) on Cholesky without a
shift, the buckling transformation (K + σ K_σ)⁻¹ K on LDLᵀ with one, whose inertia counts the
load factors below σ (Grimes–Lewis–Simon 1994). Lanczos gains an operand and an eigenvalue map
(defaults keep frequency steps bit for bit) and reports converged negative eigenvalues. Results
are frequency results with a `buckling` part; modes display with their load factor.
solve.buckle (in the Static drop-down); Abaqus *BUCKLE, Nastran SOL 105 and LS-DYNA refuse it by
name. Euler columns of hex20 within 0.18 % of Engesser's load.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UhhZMBTviDQxZvwnyP89fo
2026-10-14 13:30:59 -04:00