buckle-euler-pinned and buckle-euler-cantilever (hex20 columns, −0.18 % from Euler with Engesser's shear correction) and buckle-plate-square (a simply supported square plate, b/t = 100, −0.39 % from k = 4; the support and thickness choices in its README). ROADMAP and parity updated, docs/oracle.md regenerated. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01UhhZMBTviDQxZvwnyP89fo
402 B
402 B
Euler buckling of a pinned column of solids
A pinned–pinned square column, length 20, side 1, E = 1000, ν = 0, modelled as its half with a symmetry plane at midspan (2 × 2 × 10 hex20). The pinned end is held laterally over its face, which leaves its rotation free, and pressed by a unit pressure; the first load factor is the buckling stress. Reference: Euler with Engesser's shear correction.