The oracle binary (modelcraft-testkit) runs each case's recipe through the
command engine, measures its quantities by JSON pointers into step outputs
or commands, compares them with the cited references and the frozen
fixtures, and writes docs/oracle.md. 20 theory cases (patch tests of every
solid element, Timoshenko cantilevers, Lame, Kirsch, beam frequencies,
torsion and bending through couplings, explicit waves and impact, CDT
invariants), 8 published benchmarks (MacNeal-Harder patch, straight and
curved cantilevers, thick cylinder, Scordelis-Lo with solids, NAFEMS LE1,
LE10, FV32) and 10 pending cases with citations.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01NmAttHhUZTokgPeEJia8sm
2026-10-13 21:42:19 -04:00

337 B
Raw Blame History

Elastic bar striking a rigid wall (explicit)

A bar 10 × 0.1 × 0.1 of 200 one-point hex8 elements (E = 10⁴, ρ = 1, ν = 0, c = 100) moving at v₀ = 0.1 towards a frictionless rigid wall at x = 0 (its end face is the contact set); linear bulk viscosity off. Solved to t = 0.3: in contact from 0 to 2L/c = 0.2, then free at +v₀.