file.sample heated-bracket: the corpus filleted bracket in steel, tet10, its hole bores clamped, the upright's end held at 120 C and the rest cooled by still air; one coupled temperature-displacement step. Its test checks the temperatures against the heater and the air, then warms the bracket evenly, clamps one hole, and matches the free thermal expansion alpha dT times the distance from the hole along x. Closes #165 Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01UhhZMBTviDQxZvwnyP89fo
6.0 KiB
Examples
Every example is a built-in sample: open it from File ▸ Samples (or the start screen), with
fieldcraft --sample NAME, or with the file.sample command ({"name": "drop-test"}), then
press Solve (solve.run). Each opens fully defined — geometry, mesh, materials, boundary
conditions, loads and steps — in mm, t, s, N and MPa, and opens and solves within half a minute. The geometry is our
own: SolidCraft scripts run when the sample opens (a recipe from tests/corpus
or one written in crates/engine/src/sample.rs). Each sample has a test in
crates/engine/src/sample.rs that opens it, checks it clean, solves it and holds its result to
the check given below.
Drop test (drop-test)
An aluminium L-bracket (60 × 40 mm foot, 50 mm upright, 8 mm thick, R6 fillet) falls 2 m onto a rigid floor tilted 15°, so the end of its foot strikes first. Explicit dynamics for 1 ms with gravity: 1 911 swept hex8 elements (one-point, stiffness hourglass control), bilinear plasticity (yield 240 MPa), the floor a rigid wall. About 8 400 increments, a few seconds.
Look at: the frames from the strike (Results ▸ Frame): the compression wave leaves the struck corner and the upright's inertia bends the fillet, where von Mises peaks near 120 MPa — below yield, so the drop leaves no permanent set. The energies plot shows the kinetic energy turning into vibration with a balance under 0.01 %.
Check: the mass equals ρ V of the bracket (0.5 %); it meets the floor at √(2 g h) = 6.26 m/s, with ½ m v² = 1 748 mJ of kinetic energy (1 %); energy is conserved (balance < 1 %); by 1 ms the floor has taken about half its downward momentum.
Rubber seal (rubber-seal)
A rubber gasket ring (20 mm inside radius, 30 mm outside, 10 mm high) squeezed 2.5 mm (25 %) between two plates bonded to it. Generic rubber, E = 6 MPa, ν = 0.49, Mooney–Rivlin with C01 = 0.2 MPa; 1 000 hybrid (u–p) hex8 elements in four mapped quarter blocks. Nonlinear static with large deformation: Newton–Raphson in nine increments, under a second.
Look at: the deformed shape at scale 1 — the free inner and outer walls bulge out, and von Mises peaks (about 7 MPa) where the bulge meets the bonded plates. Results ▸ Increment steps through the converged increments.
Check: the same ring between frictionless plates compresses evenly, and its force matches the closed form for an incompressible Mooney–Rivlin solid in uniaxial compression, P = 2 (λ − λ⁻²)(C10 + C01/λ) per original area: 3 430 N against 3 466 N (within 3 %). Bonded, the bulge makes it stiffer (shape factor 0.5): 6 518 N, held between 1.05 and 2.5 times the frictionless force. The groove and the plates are prescribed displacements today; with implicit contact (#161) the ring will be pressed by contact against a groove.
Flow past a bracket (flow-past)
Air (ρ = 1.2 kg/m³, μ = 1.8 × 10⁻⁵ Pa s) at 25 mm/s past the same L-bracket standing on the floor, the upright's back to the wind. A 240 × 120 × 100 mm box of 2.5 mm cells (184 320), uniform inlet, outlet at zero pressure, a no-slip floor and slip walls at the sides and top; D3Q19 lattice Boltzmann (TRT) for 16 s, about 6.7 flow-throughs, ten frames. Reynolds number 83 on the upright's 50 mm height: laminar, a steady wake. About 10 s.
Look at: the step's report (solve.fluid, or Results after Solve): the force on every
named face of the bracket and on each side of the box, final and time-averaged, and the mass
history; solve.probe with points gives the velocity and pressure in any cell, and with
forces each face's force history.
Check: the drag on the bracket, as a coefficient on the upright's frontal area (40 × 50 mm), is 2.3 — a bluff plate standing on a wall at low Reynolds number in a box it blocks by 17 %, held between 1 and 3.5 (a flat plate broadside to the flow is about 1.2 at high Reynolds number and rises as it falls); the lattice's mass changes by less than 1 %.
There is no picture yet: the viewport does not draw flow results (velocity slices and streamlines are planned in M12), so this example is numbers only for now.
Heated bracket (heated-bracket)
The corpus filleted bracket (tests/corpus/filleted-bracket: an 8 mm L-bracket, R6 fillet, a
hole through each leg) in steel, both hole bores clamped. The end of the upright is held at
120 °C by a heater; the rest of its outside loses heat to still air at 20 °C
(h = 10 W/(m² K)); steel conducts with k = 50 W/(m K), expands with α = 12 × 10⁻⁶/K and is
stress free at 20 °C. One coupled temperature–displacement step (steady) on 23 641 tet10
elements: about 8 s to open (meshing) and 13 s to solve.
Look at: Contours ▸ Temperature: the upright stays within a few degrees of the heater and the foot falls to 95 °C, a steady balance between conduction and the air. Contours ▸ Von Mises shows the stress of the growth the clamps hold back: tens of MPa through the legs, peaking at the edges of the clamped bores, where a rigid clamp is a stress singularity (about 1 GPa there, a figure that grows as the mesh is refined: read the stress a little away from the bore).
Check: the temperatures lie between the air's and the heater's and fall away from the heater. For the expansion, the test puts the air at the heater's temperature, so the bracket warms evenly by ΔT = 100 K, and clamps the foot's hole alone: the bracket then grows freely about it, and a point moves α ΔT times its distance from the hole's axis. The upright's top moves −0.0432 mm along x (within 2 %); the foot's end, 16 mm from the clamped bore, which cannot grow, moves 0.0228 mm against 0.024 mm (within 6 %).