f525704192 test: failing regression test for #268: Panic from truck-topology lib.rs:186 when joining struts that end on a bore wall (#283)
* test: reproduce #268 (Panic from truck-topology lib.rs:186 when joining struts that end on a bore wall)

* Sew refuses edges whose ends weld to one vertex (#268)

The sewer welds vertices on a 1e-6 grid but only rejected edges shorter than
1e-9, so a sliver edge between the two welded its ends into one vertex and
truck-topology panicked ("Two same vertices cannot construct an edge") inside
the guard. Such an edge is now a degenerate-edge error before any truck call,
and the boolean takes its usual fallback.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>

---------

Co-authored-by: bherbruck <brennen.herbruck@gmail.com>
Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-12 11:18:24 -04:00
..