Files
jyvikoandClaude Opus 5.5 7a69fe5e2f verification: implicit plasticity oracle cases and documentation
Four cases, each against its closed form: uniaxial tension of a J2 cube to a
logarithmic strain of 0.2 (Kirchhoff stress exact; 0.13 % from the explicit
solver's hypoelastic Cauchy stress, the elastic volume change between the two
laws), the Bauschinger effect of linear kinematic hardening on a load path
back to zero strain (exact), Hill's elastic-perfectly plastic thick cylinder
(bore displacement at a plastic radius of 1.5a within 0.009 %, collapse
pressure within 2e-8; the pending case is now active) and a cantilever's
plastic collapse, converged 3.1 % above beam theory's hinge, the bound a
continuum exceeds. docs/fem.md, the literature, ROADMAP (M15), parity and the
oracle page follow.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01NmAttHhUZTokgPeEJia8sm
2026-10-14 06:03:36 -04:00

14 lines
928 B
Markdown
Raw Permalink Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# Plastic collapse of a cantilever
A steel bar 200 long with a 10 × 10 section (E = 200000, ν = 0.3, elastic–perfectly plastic at
σ_y = 250), reduced hex20 20 × 2 × 4, in a nonlinear static step without nonlinear geometry. The
root x = 0 is a plane of symmetry (no rotation, the section free to contract laterally), held in
Y, Z and against twist on average through a distributing coupling; a coupling at the tip pushes
the end down by 15, 4.5 times the deflection at first yield.
Beam theory's collapse is a plastic hinge at the root: M_p = σ_y b h²/4 = 62500 and
P_c = M_p/L = 312.5. The solid's collapse lies above it, since a continuum cannot rotate about a
hinge (that needs a jump of the normal velocity across the section): refined to 8 elements
through the depth or 160 along the length, the force settles at 322.3, 3.1 % above. The case
checks that the implicit plasticity reaches this plateau and holds it.